Trung tâm báo cháy HCP-204

  • 4 class B (style B) initiating circuits which maybe configured.
  • 5 zones Control panel.
  • Hochiki’s HCP-204 Fire Alarm Control Panel is a microprocessor based unit designed for small to medium commercial, institutional and industrial occupancies. Fully configurable using DIP switches, it enables the user to configure the system to meet their specific requirements.
  • The HCP-204 comes standard with 4 Class B (Style B) Initiating Circuits which may be configured as 2 Class A (Style D) circuits. In addition it comes equipped with 2 Class A/B (Style Z/Y) Indicating circuits which are each rated at 1.25 amps. The panel also includes a 2.75 Amp Power Supply which powers the system and supplies a 4-wire resettable regulated smoke power supply of 24 VDC 100mA maximum.
  • The HCP-204 utilizes a simple DIP switch configuration for programming initiating and indicating circuits as well as the enabling and disabling of system functions such as Signal Silence, Fire Drill and Auxiliary Disconnect. Some predefined Initiating circuits can optionally be configured as Waterflow or Latching/Non-Latching Supervisory. In addition the HCP-204 allows for Alarm.
  • Verification on the initiating circuits. The Indicating circuits may be configured as Silenceable or Non-Silenceable with the audibles configured for Steady, March-Time, Temporal Code, or California Code. The HCP-204 is equipped with auxiliary relay contacts for Common Alarm, Trouble and Supervisory. If no Supervisory circuits are enabled, the Supervisory relay becomes a second Alarm relay.
  • The cabinet is available in a beige color for the Canadian market and a red exterior for the U.S. and International markets. A Fire Retardant Lexan Window in the hinged door allows for viewing of the status LEDs. It comes with a durable CAT-30 lock and key. Space is provided for up to 10 AH batteries.
  • 4 Class B (Style B) Initiating Circuits which may be configured as 2 Class A (Style D) circuits.
  • 2 Class A/B (Style Z/Y) Indicating Circuits with individual trouble indicators (1.25 Amps max. per circuit.)
  • Each Indicating Circuit can be configured as Silenceable or Non-Silenceable. Audibles may be configured as Steady, Temporal Code, California Code or March Time
  • Selectable Alarm Verification on Initiating Circuits
  • Output for 4-wire resettable regulated smoke power supply of 24 VDC 100mA maximum
  • Output for RTI or Remote Annunciators of 24VDC, 300 mA max, unfiltered
  • Built-in Walk Test operation
  • Auxiliary relay contacts for Common Alarm, Common Trouble and Common Supervisory. If no Supervisory circuits are enabled, the Supervisory relay becomes a second Alarm relay.
  •  2.75 Amp Power Supply
  • Easy configuration via DIP switches